Accuway
TM with handheld readouts
- Handheld Readouts.
- Made from a Lightweight Aerospace Alloy.
- Available Hermetically sealed for use in wet conditions.
- Units have a 5 metre cable close coupled to a 4 digit
15mm LCD display.
- Tare, Peak and Reset facility.
- The power source is a 9V PP3 battery, can be supplied for
mains power if required (240v).
- All units are calibrated to comply with ISO 7500-1: 2004.
- The accuracy of the cells are better then 1% of applied load.
- Complete with carry case.
- 12 Month Guarantee, subject to conditions.
Options:
12V Mains Operation
Monitor can be supplied with a socket for operation from a mains plug
top, 240 to 12 volt power supply.
The unit can be scaled Tonne, Kilograms or KN’s
The above can be supplied with longer monitor cables if required
Range of sizes we offer are: 2.0 tonne, 5.0 tonne, 10.0 tonne, 20.0
tonne, 50.0 tonne & 100.0 tonne. Plus specials
Click here for the full Accuway
TM specification...
Click here to download Accuway TM specification PDF
Accuway
CM with handheld readouts
- Handheld Readouts.
- Made from a Lightweight Aerospace Alloy.
- Available Hermetically sealed for use in wet conditions.
- Tare, Peak and Reset facility.
- Units have a 5 metre cable close coupled to a 4
digit 15mm LCD display.
- All units are calibrated to comply with ISO 7500-1: 2004.
- The accuracy of the cells are better than
1% of applied load.
- The power source is a 9V PP3 battery, can be
supplied for mains power if required (240v).
- 12 Month Guarantee, subject to conditions.
- Complete with carry case.
Options:
12V Mains Operation
Monitor can be supplied with a socket for operation from a mains
plug top, 240 to 12 volt power supply.
The unit can be scaled Tonne, Kilograms or KN’s
The above can be supplied with longer monitor cables if required
Range of sizes we offer are: 2.0 tonne, 5.0 tonne, 10.0 tonne, 20.0
tonne, 50.0 tonne & 100.0 tonne. Plus specials
Click here for the full Accuway
CM specification...
Click here to download Accuway CM specification PDF
Accuway
TMIR - Infrared Operation
- The cell is manufactured in aluminium alloy with HT steel bushes.
- The cell incorporates an eight gauge bridge together with
associated electronics and a 9 volt PP3 non-rechargeable battery.
- Built into the load cell is a large [20mm] 3.5 digit liquid
crystal display mounted on the front of the cell for easy reading from
the operator’s
position.
- The load cell is self contained and has no external cabling.
- A battery switch is provided on the rear of the cell to prolong
battery life when the cell is out of use.
- All set up and calibration
data is retained when switched off.
- The cell is automatically switched off after 15 minutes to prolong
battery life.
- Battery life – typically 50 hours.
Note :- The tare and peak readings are stored even
after
an automatic 15 minute shut down, the tare and peak reading
being returned at next ‘on’ press of the remote, [provided
the cell rear button has not been switched off.] * Automatic range change
is available when appropriate.
| Dimensions |
| Capacity |
Length |
Width |
Depth |
Hole Dia. |
Hole Centres |
| 5 Tonne |
275mm |
100mm |
50mm |
26mm |
200mm |
| 10 Tonne |
320mm |
110mm |
50mm |
36mm |
220mm |
| 20 Tonne |
360mm |
140mm |
50mm |
52mm |
240mm |
| 50 Tonne |
442mm |
160mm |
75mm |
72mm |
272mm |
Accuway TMIR - Infrared Operation
- Control is via a hand held controller.
- Size – 95 x 60 x 40
mm.
- Battery – 1 x PP3 non-rechargeable
- Battery life – many
tens/hundreds of hours depending on use.
- Mounted on the controller are
four momentary action push buttons. These buttons perform the following
functions :- On/Off.
- Zero/Tare – button will tare up to 10% of
cell capacity.
- Peak – retains the highest load applied since selecting
Peak or resetting.
- Reset – resets the peak reading
- Range – The infrared controller
will operate in bright ambient light
conditions, however, it will not operate if the cell is directly facing
into the sun.
- The minimum range is 5 metres, typically 7 metres.
Click here to download Accuway TMIR specification PDF
Accuway
SMIR - Infrared Operation
- The cell is manufactured in aluminium alloy with HT steel bushes.
- The cell incorporates an eight gauge bridge together with
associated electronics and a 9 volt PP3 non-rechargeable battery.
- Built into the load cell is a large [20mm] 3.5 digit liquid
crystal display mounted on the front of the cell for easy reading from
the operator’s
position.
- The load cell is self contained and has no external cabling.
- A battery switch is provided on the rear of the cell to prolong
battery life when the cell is out of use.
- All set up and calibration
data is retained when switched off.
- The cell is automatically switched off after 15 minutes to prolong
battery life.
- Battery life – typically 50 hours.
Note :- The tare and peak readings are stored even
after
an automatic 15 minute shut down, the tare and peak reading
being returned at next ‘on’ press of the remote, [provided
the cell rear button has not been switched off.] * Automatic range change
is available when appropriate.
Accuway SMIR - Infrared Operation
- Control is via a hand held controller.
- Size – 95 x 60 x 40
mm.
- Battery – 1 x PP3 non-rechargeable
- Battery life – many
tens/hundreds of hours depending on use.
- Mounted on the controller are
four momentary action push buttons. These buttons perform the following
functions :- On/Off.
- Zero/Tare – button will tare up to 10% of
cell capacity.
- Peak – retains the highest load applied since selecting
Peak or resetting.
- Reset – resets the peak reading
- Range – The infrared controller
will operate in bright ambient light
conditions, however, it will not operate if the cell is directly facing
into the sun.
- The minimum range is 5 metres, typically 7 metres.
Click here to download Accuway smir specification PDF
|